<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-24 17-30-05
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 56 dBuV VOLTAGE
Pilot RDS Phase Difference
7.1 kHz 3.6 kHz -71 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 75 kHz 10060 56,2326
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
7,4 dBr 8,08 dBr 8,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 10 (Pop M) 1 0 0 5 17:30, 24.03.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (54 dBuV) Max at: 75 kHz MIN: 10 kHz % above 76 kHz: 56,2326 Acquired: 2025/03/24 17:29:01 Total samples: 10060 Equivalent time: 0:08:23 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 8,6 dBr MIN: 7,4 dBr AVE: 8,08 dBr % above 10,2 dBr: 0,0 Last value: 7,8 dBr (2025/03/24 17:29:01) Station: 96.90 MHz, signal: 4/5 (54 dBuV) 17:22 17:23 17:24 17:25 17:26 17:27 17:28 17:29 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality